How the checks work
Every plan on this site is generated from the same engine. You describe the building, and the engine places every board, sizes it, and then checks the result. Here is what it checks and what it doesn't.
Each board is a real 3D solid
Every stud, rafter, joist and sheet is modelled with its actual cuts: mitres, birdsmouth notches, the side cuts where jack rafters meet a hip, the notches in a stair stringer. The engine then tests every piece against every other piece. If two boards would occupy the same space by more than 1/50″, the plan fails and says which two.
Every piece connects to the ground
Starting from the footings or slab, the engine follows contact from piece to piece. Anything that isn't reached is floating, and the plan fails.
Members are sized by calculation
Joists, beams, rafters, hips, headers, studs and posts are checked for bending, shear and deflection using design values from the National Design Specification for wood. Snow load comes from your ground snow figure; floors use 40 psf live load, 50 for workshops. Rafter notches get the notched-end shear check. Posts get a buckling check, footings a bearing check, and gazebo roofs a check of the outward thrust at the corners.
What isn't checked
Wind and earthquake bracing, frost depth, soil conditions and local amendments to the code. Those vary by town. Take the plan to your building department; the proof section gives them the numbers.